Skip to main content
GeoSolar — Geo Solarworks Technology
Suntree SRD-30 DC 1000V 1100V 15A Solar PV Fuse Holder and Fuse Link

SuntreeElectrical Protection

Suntree SRD-30 DC 1000V 1100V 15A Solar PV Fuse Holder and Fuse Link

Suntree SRD-30 solar PV fuse holder and 15A fuse link in Kenya rated 1000V/1100V DC, taking 10x38mm fuses to protect individual PV strings.

  • 1000V
  • 1100V
  • 15A
Ksh 700

KES, including 16% VAT where applicable

Out of stock

Currently out of stock. Request a quotation and we will confirm the next available date and price.

Request a quotation
  • Nairobi delivery Ksh 1,500; rest of Kenya from Ksh 4,500. Collection available.
  • Warranty terms confirmed in writing with your order or quotation.
  • Pay by Bank transfer. Approved business accounts can pay on invoice.
  • Engineer advice before you buy and support after installation.

Product overview

Suntree SRD-30 solar PV fuse holder and 15A fuse link in Kenya rated 1000V/1100V DC, taking 10x38mm fuses to protect individual PV strings.

In professional solar array design, protecting individual photovoltaic strings from overcurrent is a safety requirement, and the Suntree SRD-30 Fuse Holder provides the ideal solution. This device is specifically engineered for high-voltage DC applications, supporting a rated voltage of up to 1000V or 1100V, making it suitable for modern high-efficiency PV strings. It houses a standard 10x38mm fuse link, typically provided in a 15A or 30A rating, which acts as a sacrificial link to break the circuit in the event of a fault. A standout feature of the SRD-30 is its integrated LED light monitor; when the fuse link is ruptured due to an overcurrent event, the indicator illuminates, allowing technicians to quickly identify the failed string without the need for manual testing with a multimeter. This significantly reduces downtime and maintenance costs. The holder is designed for standard 35mm DIN rail mounting, allowing it to fit seamlessly into DC combiner boxes alongside other protection devices like MCBs and SPDs. Constructed from premium heat-resistant and flame-retardant materials, it ensures that any thermal event is contained within the device. By isolating faulty strings, the Suntree SRD-30 prevents reverse current from flowing into shaded or damaged panels, protecting your investment from fire hazards and potential energy loss. It is an indispensable component for any grid-tied or off-grid solar protect system.

Who it is for

Installers and facilities teams protecting PV strings, batteries and AC circuits with correctly rated breakers, isolators, surge protection and enclosures.

For business and commercial buyers

  • Correct protection supports safe operation and insurance requirements.
  • Itemised quotation and tax invoice from GeoSolar for your procurement file.
  • Engineer review of compatibility with your existing system before you commit.
  • Business pricing available to approved trade and corporate accounts.

Compatibility and installation

What to confirm before you buy

  • DC or AC rating, and the maximum system voltage (for example 500VDC or 1000VDC).
  • Current rating against the circuit it protects.
  • Number of poles required by the circuit design.
  • Enclosure IP rating and number of ways for the location.

Protection devices must be selected and installed by a qualified electrician. AC breakers are not interchangeable with DC breakers.

Ask an engineer to confirm compatibility

Warranty and support

Warranty terms for this product are confirmed in writing with your order or quotation. Keep your invoice: it is your proof of purchase for warranty claims.

After installation, raise support requests from your GeoSolar account, by phone or on WhatsApp. How support works

Downloads

Datasheets and installation manuals are available from our technical team. Request the datasheet

Customer reviews

No reviews yet. Bought or installed this product? Share your experience to help other buyers.

Reviews come from signed-in customers and are moderated before publishing. “Verified purchase” means the reviewer received this product on a GeoSolar order.

Write a review

Sign in to your GeoSolar account to rate and review this product.

Frequently asked questions

Can I use an AC breaker on the DC side of my solar system?

No. DC circuits need DC-rated devices, which are designed to interrupt DC arcs. Use the DC rating that matches your system voltage.

Is the price VAT inclusive?

Yes. Marketplace prices are shown in Kenyan shillings and include 16% VAT where it applies. Your tax invoice shows the VAT amount.

How does delivery work?

Nairobi delivery is Ksh 1,500 and courier delivery to the rest of Kenya starts at Ksh 4,500; heavy items are quoted. Delivery is free on orders above Ksh 500,000, and you can collect your order instead.

Can GeoSolar install this for me?

Yes. Request a quotation and choose supply and installation. An engineer confirms the design and compatibility with your site before work starts.

Request a quotation

For project quantities, supply and installation, or when you want an engineer to confirm compatibility first.

We use your details only to respond to this request. See our privacy policy.

Request business pricing

Contractors, developers and institutions buying regularly can apply for business pricing on their account. Resellers should join the partner programme.

We use your details only to respond to this request. See our privacy policy.