Skip to main content
GeoSolar — Geo Solarworks Technology
SUNTREE-DC Surge Protector 3pole 1000VDC 20kA – 40kA

SuntreeElectrical Protection

SUNTREE-DC Surge Protector 3pole 1000VDC 20kA – 40kA

Suntree 3-pole 1000VDC surge protector in Kenya rated 20–40kA, with a flash barrier and green/red status window for solar PV string protection.

  • 3pole
Ksh 3,500

KES, including 16% VAT where applicable

Out of stock

Currently out of stock. Request a quotation and we will confirm the next available date and price.

Request a quotation
  • Nairobi delivery Ksh 1,500; rest of Kenya from Ksh 4,500. Collection available.
  • Warranty terms confirmed in writing with your order or quotation.
  • Pay by Bank transfer. Approved business accounts can pay on invoice.
  • Engineer advice before you buy and support after installation.

Product overview

Suntree 3-pole 1000VDC surge protector in Kenya rated 20–40kA, with a flash barrier and green/red status window for solar PV string protection.

Investing in the SUNTREE 3-Pole 1000VDC Surge Protector is critical for safeguarding high-performance solar installations against transient overvoltages. This device is specifically engineered to dissipate heat quickly, reducing the service temperature and extending the operational life of the unit. A key safety innovation is the inclusion of a flash barrier, which prevents arc propagation during intense current impacts. The unit utilizes a green and red visual indicator system: green confirms the module is healthy, while red signals that the protection has been exhausted and requires replacement. For advanced monitoring, it supports optional remote contact signaling through a floating changeover contact. To ensure maximum safety, the design incorporates a combined disconnection and short-circuiting device with safe electrical isolation, preventing fire damage caused by DC arcs. When installing, it is recommended to maintain a minimum 10mm safety distance from other grounded parts using suitable electrical insulators. This SPD is compliant with international standards, offering a reliable defense for the DC side of your system. Its plug-in module design allows for rapid maintenance without needing to rewire the entire base. By diverting surge currents safely to the ground, this 3-pole protector ensures that the most expensive components of your solar infrastructure, such as high-voltage string inverters, are protected from atmospheric discharges and grid-related electrical spikes.

Who it is for

Installers and facilities teams protecting PV strings, batteries and AC circuits with correctly rated breakers, isolators, surge protection and enclosures.

For business and commercial buyers

  • Correct protection supports safe operation and insurance requirements.
  • Itemised quotation and tax invoice from GeoSolar for your procurement file.
  • Engineer review of compatibility with your existing system before you commit.
  • Business pricing available to approved trade and corporate accounts.

Compatibility and installation

What to confirm before you buy

  • DC or AC rating, and the maximum system voltage (for example 500VDC or 1000VDC).
  • Current rating against the circuit it protects.
  • Number of poles required by the circuit design.
  • Enclosure IP rating and number of ways for the location.

Protection devices must be selected and installed by a qualified electrician. AC breakers are not interchangeable with DC breakers.

Ask an engineer to confirm compatibility

Warranty and support

Warranty terms for this product are confirmed in writing with your order or quotation. Keep your invoice: it is your proof of purchase for warranty claims.

After installation, raise support requests from your GeoSolar account, by phone or on WhatsApp. How support works

Downloads

Datasheets and installation manuals are available from our technical team. Request the datasheet

Customer reviews

No reviews yet. Bought or installed this product? Share your experience to help other buyers.

Reviews come from signed-in customers and are moderated before publishing. “Verified purchase” means the reviewer received this product on a GeoSolar order.

Write a review

Sign in to your GeoSolar account to rate and review this product.

Frequently asked questions

Can I use an AC breaker on the DC side of my solar system?

No. DC circuits need DC-rated devices, which are designed to interrupt DC arcs. Use the DC rating that matches your system voltage.

Is the price VAT inclusive?

Yes. Marketplace prices are shown in Kenyan shillings and include 16% VAT where it applies. Your tax invoice shows the VAT amount.

How does delivery work?

Nairobi delivery is Ksh 1,500 and courier delivery to the rest of Kenya starts at Ksh 4,500; heavy items are quoted. Delivery is free on orders above Ksh 500,000, and you can collect your order instead.

Can GeoSolar install this for me?

Yes. Request a quotation and choose supply and installation. An engineer confirms the design and compatibility with your site before work starts.

Request a quotation

For project quantities, supply and installation, or when you want an engineer to confirm compatibility first.

We use your details only to respond to this request. See our privacy policy.

Request business pricing

Contractors, developers and institutions buying regularly can apply for business pricing on their account. Resellers should join the partner programme.

We use your details only to respond to this request. See our privacy policy.